Linear Actuator Shock Loads: What a Static Force Rating Doesn't Tell Y
A linear actuator rated for 6000 N sounds like it can take a 6000 N hit. It cannot — or rather, the rating never promised that. The force on the catalogue page is a static rating: the steady push or pull the actuator can deliver, and hold, while moving slowly under control. A shock load is something else entirely — a sudden impact, a dropped load, a hard stop at the end of travel — and it can briefly exceed the static rating by a large multiple. This guide explains where shock loads come from, how to think about the energy involved, and what to do about it before the mechanism is built. It does not invent a shock rating for any model, because we do not publish one.
Static force is not impact force
Read the rating the way it is written. A 6000 N actuator delivers 6000 N of steady force. That number says nothing about a load that falls onto it, slams into its end stop, or reverses direction suddenly. Our static vs dynamic load guide covers the steady-state side of this in full: dynamic load is the force while moving, static load is the force at rest, and the two are different numbers for a reason. Shock sits outside both. It is a brief spike, and the gearbox, screw, and mounts feel the spike, not the average.
The honest rule is simple: size the actuator for the steady load, then check separately whether anything in the mechanism can hit it. If the answer is yes, the fix is in the mechanism — damping, stops, geometry, derating — not in buying a bigger catalogue number and hoping.
Where shock loads come from
A dropped or falling load. The classic case. A lid, bed, or panel that is lowered too fast, slips from a hand, or drops when a latch releases arrives at the actuator with speed it did not have a moment before. Gravity does the accelerating; the actuator does the stopping, in millimetres. The force spike depends on how far the load falls and how abruptly it is stopped, not on how heavy the catalogue says the actuator is.
Hitting the end stop. Every actuator in our line has built-in limit switches that stop travel at both ends — but the switch stops the motor, and the moving load still carries momentum. If the load is heavy and the speed is high, the last few millimetres of travel end with the mechanism absorbing the remaining energy. A load that stops gently at mid-stroke and one that runs into the end of its travel at full speed are different events, even though the force rating is the same.
Backdriving and overhauling loads. Some loads try to drive the actuator backwards — a heavy lid closing under its own weight, a bed tipping past balance, a load on a slope. The actuator resists, and the screw and gearbox take the load in reverse. Our actuators hold position at rest — the self-locking forces are in the table below — but holding still and being backdriven are different things, and a load that overhauls the actuator is working against the mechanism rather than with it.
Sudden reversals. Extend, stop, retract, stop — a mechanism that changes direction quickly, or that is driven by an operator who slams the switch back and forth, puts repeated impact cycles through the gearbox. One reversal is nothing; thousands of them are fatigue.
End-stop energy: a worked example
Energy is the right way to think about a shock, because the damage depends on how much energy has to go somewhere in how short a distance. The method is ordinary physics, and the numbers below are a worked example with assumed values, to show the method — they are not a rating for any product.
A moving load carries kinetic energy: ½ × mass × speed². Take a 50 kg load moving at 7 mm/s — the full-load speed of our fastest heavy models. Its kinetic energy is ½ × 50 × (0.007 m/s)² ≈ 0.0012 joules. Almost nothing. That is why a slow actuator under control is gentle: at millimetres per second, there is hardly any energy to absorb.
Now drop the same 50 kg load by 100 mm onto the actuator. The energy is mass × gravity × height: 50 × 9.81 × 0.1 ≈ 49 joules — roughly forty thousand times more. Same load, same actuator, and the difference between a controlled move and a short drop is four orders of magnitude of energy that the screw, gearbox, and mounts have to absorb in a fraction of a second.
The lesson is not the exact numbers — your load and your drop are different — it is the shape of the problem. Slow, controlled motion is cheap in energy. Drops and hard stops are expensive. If your mechanism can drop a load onto the actuator, even a short distance, that is the load case that matters, and it is the one the catalogue force rating does not cover.
Self-locking is a static hold, not a shock rating
Our actuators hold position at rest, and the holding forces are real numbers from our product pages:
| Model | Force | Self-locking force |
|---|---|---|
| HH-LA-U1 | 900 N (pull 800 N) | 1500 N |
| HH-LA-U2 | 1500 N (pull 1100 N) | 1800 N |
| HH-LA-U8 | 4000 N (5 mm/s grade) | 4000 N |
| HH-LA-U11 | 3500 N | 5000 N |
| HH-LA-U3 | 6000 N (pull 4000 N) | 8000 N |
| HH-LA-U6 | 7000 N | 9000 N |
| HH-LA-U7 | 12000 N | 15000 N |
Read that table carefully: self-locking force is the static load the actuator holds without power. A shock spike can exceed it briefly, and when it does, the actuator may slip a little rather than break — which is a survivable event, not a design target. Never treat the self-locking number as an impact allowance. Our self-locking guide explains what the holding force means and what it does not, and the same warning applies here: a raised load held only by the actuator needs a mechanical prop or safety pin before anyone works underneath it.
Five things that actually reduce shock loads
1. Slow down near the ends. The cheapest fix. If the operator can see the end of travel coming, the actuator arrives slowly and the limit switch finishes a job that is nearly done. For heavy lids and beds, brief the operator — or wire the control so the last part of travel is a deliberate, slow press rather than a held button.
2. Put a mechanical stop in the mechanism, not in the actuator. A rubber bumper, a steel stop block, or a gas strut that takes the last of the travel means the energy goes into a part designed to take it. The actuator's built-in limit switches stop the motor; they are not shock absorbers.
3. Derate for impact. If the mechanism can hit the actuator, do not size to the edge of the rating. Pick the model with margin above the steady load, and shorten the drop or the free travel wherever the design allows. A load that calculates to 5000 N steady does not get a 6000 N actuator when it can also fall — it gets a bigger one, or a redesign that removes the fall.
4. Mount rigidly, and keep the push in a straight line. A shock load that arrives off-axis bends the rod and loads the gearbox sideways, which is worse than the same force arriving straight. Mount on solid structure, keep both ends aligned, and never let the actuator carry a side load. See our mounting guide.
5. Protect the electrics against a stall. A shock that jams the mechanism stalls the motor, and a stalled motor draws full-load current until something gives. Fit an inline fuse rated above the full-load current — our fuse guide explains why — and check the mechanism before resetting a fuse after a stall. The fuse protects the wiring and the motor; it does not protect the gearbox from the impact itself.
Two more habits belong on the same list. Respect the duty cycle: the U7 is rated 25%, the U2, U3, U8, and U11 at 10–20% — an actuator that runs hot from continuous cycling has less margin for anything else, and our duty cycle guide explains the rating. And inspect after an event: if a load has dropped onto the actuator, check the mounts, the rod, and the travel before the next cycle. Our troubleshooting checklist and maintenance guide cover what to look for.
When to ask us before you order
Bring us the mechanism if any of these are true: the load can fall onto the actuator, even a short distance; the load overhauls the actuator on part of its travel; the actuator is the only thing stopping a heavy lid or bed at the end of its travel; or the mechanism reverses under load many times a day. Send us the weight, the geometry, and what moves — the answer is usually one line, and it is cheaper to get it right before the steel is cut. For volume, distributor, or OEM orders, see our Bulk & OEM/ODM page.
FAQ
Can I size an actuator from its force rating alone if there are shock loads?
No. The force rating covers steady load. If the mechanism can drop, slam, or overhaul, that load case has to be handled in the mechanism — damping, stops, derating — or brought to us with the numbers before you order.
Will a bigger actuator solve a shock problem?
Partly. More margin helps, but a bigger model does not turn a dropping load into a gentle one. Removing the drop, or putting a stop in the mechanism, does more than stepping up one model.
Does the built-in limit switch protect against end-stop impact?
It stops the motor at the end of travel, but the moving load still carries momentum into the last millimetres. Slow down near the ends and give the mechanism its own stop.
Can a shock load backdrive the actuator?
A brief spike can exceed the static self-locking force, and the actuator may slip a little. That is a survivable event, not a design target — and it is why a raised load needs a mechanical prop, not just the actuator, holding it.
What should I check after a load drops onto the actuator?
Check the mounts for loosening, the rod for bending, and run the full travel slowly, listening for new noise and watching for uneven movement. If anything has changed, stop and inspect — or contact us with photos before running it again.
Do you publish a shock or impact rating for your actuators?
No. We do not claim an impact rating for any model, and this guide does not invent one. If your application has severe repeated impact, talk to us with the actual load profile before ordering.
Actuators in this guide carry a 12-month warranty; check the product page for the current terms. Our U-series actuators are covered by a UDEM certificate of conformity (valid to 2028-04-23) for the JS-TGZ-U1–U12 range — see our CE guide for what the certificate covers. Brackets fit the U1/U2 (angled bracket) and U3 (U-bracket) only, are ordered with the actuator, and are not sold separately.
For the rest of the project, start with our how to choose an electric linear actuator, our selection guide, and our full model comparison. Related reading: our static vs dynamic load guide, self-locking guide, industrial hatch guide, off-highway machinery guide, and conveyor retrofit guide cover the same honest-limits thinking in neighbouring applications.