Linear Actuators for Conveyor and Factory Equipment Retrofits: Where T

Upgrading conveyor and factory equipment does not always mean replacing a machine. Many of the adjustments that operators still do by hand — moving a guide rail for a new product width, swinging a chute, opening a gate, raising a work height — are short, straight, intermittent motions. Those are exactly what an electric linear actuator does well. This guide explains where actuators genuinely fit in a conveyor or factory retrofit, how to select one honestly, and where the boundary is: the three things an actuator must never be asked to do.

The boundary matters more than the sales pitch. An actuator used inside its limits is a cheap, reliable upgrade. An actuator used outside them — as a belt drive, as a structural support, as a continuous-duty motor — fails early, and the failure usually takes the production line down with it.

Four retrofits that work

Guide rails. Conveyor guide rails move sideways for product changeovers: a wider carton, a different bottle, a new pack size. The motion is short, the load is mostly friction and the weight of the rail itself, and the position must repeat. One small actuator per rail section, with built-in limit switches stopping travel at both ends, replaces a manual crank and a locking handle — and it makes changeovers repeatable instead of approximate.

Chutes and diverters. A diverter plate or chute flap swings through a short arc to send product down one lane or another. The load is the plate plus the product resting on it at the moment of movement. Short stroke, moderate force, and a sealed body matter more here than speed. Dust is part of the job, so pick the protection rating for the environment, not for the catalogue.

Gates and dampers. A gate that opens a hopper, a damper that opens a ventilation path, a flap that closes a dust outlet. These are hinge problems — the same hinge calculation as a lid or a door — and the actuator only needs to overcome the turning moment at the closed position, where the load is worst. Our industrial hatch guide works through that calculation step by step.

Height adjustment and fixturing. Raising a work table, positioning a sensor head, clamping a fixture for a production run. These are straight push-pull jobs with a defined load, and they are where an actuator's stop-anywhere positioning earns its keep. Our track actuator guide covers the guided variant, for jobs where the load must travel on a rail rather than on the actuator rod itself.

Three things an actuator must never do

Drive a conveyor belt. A belt needs continuous rotation; an actuator produces straight-line motion over a limited stroke. No actuator in our line drives a belt, a roller, or a rotary mechanism. If someone offers you an actuator as a belt drive, they are selling you the wrong product. The belt keeps its own motor and gearbox; the actuator automates the adjustments around it.

Run continuously. Every model in our line is rated for intermittent duty, not continuous running. The U7 runs at 25% duty; the U2, U3, U8, and U11 run at 10–20%. A guide rail that moves for a changeover and then waits fits easily. A mechanism that must cycle back and forth all shift does not fit any of these ratings — that is a different drive system. The duty cycle section below shows how to do the arithmetic honestly.

Carry side loads or replace guides. An actuator pushes in a straight line. It is not a linear guide, not a structural support, and not a shock absorber. If the load can push sideways on the rod, the rod will bend and the seals will fail — that is a mounting failure, not a force failure. The machine's own guides and structure must carry the load and keep it aligned; the actuator only provides the push. The same applies to impact: we publish no shock or pulse-load rating for any model, and this guide does not invent one. If your mechanism sees repeated impact, talk to us with the actual load profile before ordering.

Selection: six things to check, in order

Check What it decides How to decide it
Force Whether it moves at all Weigh the moving load; for a hinged gate or flap, run the hinge calculation
Stroke Whether it reaches both ends Measure the travel the mechanism actually needs, then check retracted length
Loaded speed Whether the cycle time works Use full-load speed, not no-load speed
Duty cycle Whether it survives the shift Count cycles per hour and do the arithmetic below
IP rating Whether it survives the environment Match the rating to dust, water, and washdown
Control Whether it integrates Wired kit, wireless kit, or the machine's own control — see the compatibility guide

Our how to choose guide covers the same six checks for any project, and our selection guide puts them in one place.

Which model fits a retrofit?

Model Force Self-locking Speed, no-load / full-load Notes for factory use
HH-LA-U1 900 N (pull 800 N) 1500 N 10 / 7 mm/s Light guide rails and flaps; IP54
HH-LA-U2 1500 N (pull 1100 N) 1800 N 6 / 4.5 mm/s Guide rails, small gates; IP54; under 45 dB
HH-LA-U8 4000 N (5 mm/s grade) 4000 N 5 / 3.5 mm/s Mid-range gates and chutes; IP54; under 40 dB
HH-LA-U11 3500 N 5000 N 3.5 / 2.2 mm/s Heavy gates; IP65; under 55 dB
HH-LA-U3 6000 N (pull 4000 N) 8000 N 5 / 3.5 mm/s Heavy gates and height adjustment; IP54; under 40 dB
HH-LA-U6 7000 N 9000 N 9 / 7 mm/s Heavy-duty, push and pull equal; IP65; a signal output is listed on the product page
HH-LA-U7 12000 N 15000 N 6.5 / 4.5 mm/s The heavy line; IP66; −26 °C rated

Protection ratings, plainly: IP54 (U1/U2/U3/U8) resists dust and splashes; IP65 (U11/U6) is dust-tight and resists water jets; IP66 (U7) resists powerful water jets. None of these ratings means submersion, and none covers a pressure washer at close range. Read our IP ratings guide before you assume more than the rating promises. And if the line runs through winter in an unheated building, the U7 is rated to −26 °C and the U2, U3, U8, and U11 to −20 °C — see our cold weather guide.

Stroke and retracted length decide whether the actuator physically fits the machine: the U1 retracts to stroke + 105 mm, the U3 to stroke + 175 mm, the U11 to stroke + 120 mm, the U8 to stroke + 110 mm (or + 120 mm for strokes of 300 mm and over), the U7 to stroke + 200 mm. Measure the space the actuator has in its shortest position, then check it. Our fit check guide and stroke measurement guide walk through the measurement. Retail strokes run to 450 mm (the U7 in stock to 500 mm); longer is a message-us custom order.

The duty cycle arithmetic

A 10–20% duty cycle means roughly 2 minutes of running in every 10, with rest in between; the U7 at 25% allows a little more. Do the arithmetic for your line before you order:

  1. Time one cycle — how many seconds the actuator actually runs per movement, at full-load speed, not no-load speed.
  2. Count cycles per hour — how many movements the mechanism makes in a typical production hour.
  3. Multiply — running seconds per hour, divided by 3600, is the duty cycle. If the answer is above the model's rating, the actuator will overheat and fail early.

A guide rail that moves twice per changeover and waits the rest of the hour is at a fraction of one percent — any model fits. A diverter that fires every minute all shift is a different answer, and the honest answer may be that no actuator in our line fits that job. Our duty cycle guide explains the rating in full, and our speed guide covers the force-speed trade-off: the heavy models are slow, and on a factory floor that is usually a safety feature, not a flaw.

Power and control

Size the supply and the fuse from full-load current, not no-load current — our power supply guide has the verified table:

Model Full-load current, 12V Full-load current, 24V
HH-LA-U1 3.0 A 1.8 A
HH-LA-U2 3.8 A 2.0 A
HH-LA-U3 8.5 A 3.8 A
HH-LA-U6 16.0 A 9.0 A
HH-LA-U7 20 A 10.5 A
HH-LA-U8 7 A 4 A
HH-LA-U11 6.0 A 3.0 A

Fit an inline fuse rated above the full-load current — our fuse guide explains why, and what to check before you reset one after a stall. If you are still choosing between voltages, our 12V vs 24V guide covers the trade-offs, and our long-wire voltage drop guide covers the run-length problem on a long line.

Controllers are sold separately — a wired control kit with a handset, or a wireless remote kit. See our wiring guide and controller compatibility guide before ordering, especially if the actuator must answer to the machine's own PLC or control panel rather than a handset — that integration is a conversation, not a catalogue option. The U6 product page lists a signal output; check the page for the current specification before planning around it. We do not sell feedback or closed-loop positioning actuators, and this guide does not pretend otherwise.

Holding position matters on a line too: when a gate or rail stops, it must stay where it stopped. Our actuators hold position at rest — the U2 self-locks to 1800 N, the U8 to 4000 N, the U11 to 5000 N, the U3 to 8000 N, the U6 to 9000 N, the U7 to 15000 N. See our self-locking guide for what the number means. But self-locking is not a lock: a gate that must stay shut for safety needs a mechanical latch, and a load over a walkway needs a mechanical support independent of the actuator.

Fitting it well

  • The machine's guides carry the load, not the actuator. Fit the actuator to a mechanism that already moves freely by hand. If the rail binds by hand, the actuator will stall or bend its mounts. Fix the mechanism first.
  • Alignment is everything. The actuator must push in a straight line with the direction of travel. A few degrees of misalignment becomes a side load, and a side load becomes a bent rod. Check alignment with the mechanism at both ends of travel, not just in the middle.
  • Mounting brackets are add-ons, and only for three models. Brackets fit the U1/U2 (angled bracket) and U3 (U-bracket), are ordered with the actuator, and are not sold separately. For a U11, U6, or U7 on a machine, the mounts are custom fabrication to your machine's structure — which is normal for this kind of work. See our mounting guide.
  • Keep the rod clean. Dust, swarf, and product debris on the rod get dragged into the seals. Wipe the rod down on the maintenance round — our maintenance guide covers the routine, and our troubleshooting checklist covers what to check when a retrofit stops moving.
  • Two actuators, one mechanism: read the sync guide first. Two actuators wired in parallel do not stay in sync under uneven load — one side leads and the mechanism racks. Read our dual-actuator guide before building a two-actuator gate or rail, and design the frame so a small side-to-side difference cannot jam it.

When to talk to us

If the retrofit is one machine, order the actuator and the control kit and build it. If it is a line, a plant, or a distributor program — repeat orders, custom strokes, private-label builds — talk to us first: our Bulk & OEM/ODM page covers volume pricing and custom work, and the custom fasteners page covers the matching hardware side. Send us the load, the travel, the cycles per hour, and the environment — the answer is usually one line, and it is cheaper to get it right before the line stops.

FAQ

Can a linear actuator drive my conveyor belt?
No. A belt needs continuous rotation; an actuator produces straight-line motion over a limited stroke. Keep the belt's own motor and gearbox, and use actuators for the guide rails, gates, chutes, and height adjustments around the belt.

How many cycles per hour can it do?
Do the arithmetic: seconds of running per cycle, times cycles per hour, divided by 3600. The answer must stay under the model's duty cycle — 25% for the U7, 10–20% for the U2, U3, U8, and U11. If the number comes out above the rating, the job needs a different drive system.

Will it survive dust and washdown?
Match the rating to the exposure: IP54 for dust and splashes, IP65 for dust-tight and water jets, IP66 for powerful water jets. None of these means submersion or a pressure washer at close range. Keep the rod clean and the washer back.

Can it replace a pneumatic cylinder?
Often yes for short, intermittent motions — no air lines, no compressor, precise stop-anywhere positioning. For high-speed continuous cycling or very high force density, pneumatics or hydraulics still win. Our electric vs hydraulic vs pneumatic guide lays out the comparison.

Can two actuators lift one gate together?
They can, but they will not stay in sync under uneven load — one side leads and the gate racks. Read our dual-actuator guide and design the frame so a small difference cannot jam it.

Do you sell a feedback version for closed-loop positioning?
No. Our line is open-loop with built-in limit switches at both ends. If your application needs position feedback, tell us the requirement — we will say plainly whether we can meet it or not.

Actuators in this guide carry a 12-month warranty; check the product page for the current terms. Our U-series actuators are covered by a UDEM certificate of conformity (valid to 2028-04-23) for the JS-TGZ-U1–U12 range — see our CE guide for what the certificate covers.

For the rest of the project, start with our how to choose an electric linear actuator, our selection guide, and our full model comparison. Related reading: our track actuator guide, industrial hatch guide, off-highway machinery guide, and farm equipment guide cover the neighbouring applications, and our electric vs hydraulic vs pneumatic guide covers the drive-system choice itself.

Back to Home