What Fuse Does a Linear Actuator Need? Circuit Protection, Sized From

Two wiring mistakes show up again and again in actuator installations. The first is no fuse at all: a jammed mechanism, a stalled motor drawing everything the supply can give, and the wiring becomes the weakest link — literally, the part that heats up. The second is a fuse chosen by guesswork, which then blows on every second start until someone "fixes" it by fitting a bigger one, and the installation quietly ends up unprotected again. Both mistakes come from the same gap: nobody started from the one number that decides everything, the actuator's full-load current. This guide does.

What a fuse actually protects

A fuse is not there to protect the actuator. It is there to protect the wiring and the power source: if a fault — a stalled motor, a pinched cable, a short — makes the circuit draw far more than it should, the fuse opens before the wire insulation or the supply does. That framing decides everything else in this article:

  • The fuse must be able to carry the actuator's normal working current indefinitely, including at full load. A fuse that blows in normal use is not protection; it is a fault you installed yourself.
  • The fuse must open before current reaches a level your wiring cannot carry. Wire capacity depends on the wire itself — its gauge, insulation, length of run and how it is bundled — which is why this article will not hand you a universal wire table. Our voltage drop guide covers the wire side of the same circuit.

Start from the full-load current

These are the full-load current figures we publish. This is the number your fuse choice starts from — not the no-load figure, not a neighbour model's figure, and not the power supply's maximum unless the actuator's own draw is below it.

Model Full-load current, 12V Full-load current, 24V
HH-LA-U1 3.0 A 1.8 A
HH-LA-U2 3.8 A 2.0 A
HH-LA-U3 8.5 A 3.8 A
HH-LA-U5 3.0 A 2.8 A
HH-LA-U6 16.0 A 9.0 A
HH-LA-U7 20.0 A 10.5 A
HH-LA-U8 7.0 A 4.0 A
HH-LA-U11 6.0 A 3.0 A
Furniture line (U9 / U10 / U4 / U9-2), per actuator — (24V only) 3.8 A

Two things this table teaches. First, voltage changes the answer: the same U3 that needs protection sized around an 8.5 A draw at 12V draws only 3.8 A at 24V, so a fuse chosen for one voltage is wrong for the other — one more reason the 12V vs 24V decision comes before the wiring, not after. Second, the heavy end is genuinely heavy: a U7 at 12V is a 20 A full-load device, and its circuit — fuse, wire, switch, supply — has to be a 20 A-class circuit throughout, not just at the fuse.

For the track actuators (TP41, TP61, TP21) and the LC-01 lifting column, we do not publish a current figure, so this article will not give you a fuse recipe for them. If you are wiring one of those, ask us for the figure for your model and voltage before choosing protection — do not borrow a number from the table above.

Choosing and placing the fuse

The method, without a prescription table, because the right value depends on your circuit as well as ours:

  1. The fuse rating goes above the full-load current. Worked example, using only arithmetic: a U3 on 12V draws 8.5 A at full load, so its fuse must be rated above 8.5 A to survive normal work — a fuse at or below the working current is a planned nuisance. Start-up and a momentary hard push draw more than the steady figure, which is part of why the rating sits above it rather than at it. As a general starting point, installers often begin at about 125% of the full-load figure — on the U3 example, roughly 10.6 A before rounding to a real fuse rating — but treat that as a rule of thumb for where to start, not a prescription: the rating you fit still has to pass step 2 below and suit the switch and connectors in the circuit.
  2. The fuse rating stays below what the wiring can safely carry. That ceiling comes from your wire, not from us: use the wire maker's own rating for the gauge and insulation you installed. If the wire cannot carry more than the actuator needs, the wire is the problem — upgrade the wire, never the fuse alone.
  3. Place the fuse near the power source. The fuse protects everything downstream of it. A fuse at the actuator end of a long run leaves the whole run unprotected; a fuse at the battery or supply end protects the run, the switch gear and the actuator together.
  4. One fuse per circuit, sized for that circuit. Where two actuators share a supply — a paired lift, a two-actuator bed section — the shared feed sees the sum of both draws when both run together, and its protection has to be chosen for the sum, while each branch keeps figures based on its own actuator. Our controller compatibility guide maps which actuators are meant to run together in the first place.

A note on kits: our wired control kit's power brick is a current-limited 24V DC 2.5A source, which is its own form of protection — and also its limit. As the compatibility guide sets out, at 24V it covers the U1 (1.8 A) and U2 (2.0 A) only; a U3 at 24V already draws 3.8 A at full load and will simply run out of supply. A source that cannot feed the actuator is not a substitute for correct fusing on a supply that can.

A fuse that keeps blowing is a symptom

If a correctly chosen fuse blows repeatedly, it is reporting something. The usual reports, in the order we would check them:

  • The mechanism is jamming or overloaded. A stalled or straining motor draws well beyond its full-load figure. Free the mechanism, check the alignment against our mounting guide, and confirm the load is inside the rating.
  • The circuit is under-sized somewhere else. A long, thin run can starve the actuator of voltage, which makes it work harder and draw more — measure the voltage at the actuator terminals under load, as the voltage drop guide describes.
  • The fuse was sized from the wrong number. No-load current, the other voltage's figure, or a smaller model's row in the table. Compare what is fitted against the table above.
  • There is an intermittent short. A cable pinched by the moving mechanism itself is the classic: the fuse blows at the same point in the stroke every time.

What never belongs on this list: fitting the next fuse size up and seeing whether it stops blowing. If the bigger fuse holds, you have not fixed the fault — you have removed the alarm. Work through the cause with our troubleshooting checklist, and if the numbers stop making sense, send us the model, the voltage, the fuse fitted and when it blows; that is usually enough to locate the problem.

FAQ

Does the actuator have a built-in fuse?
Do not rely on one being there. Protection belongs to your circuit design — the fuse you fit at the source, sized from the table above. Some control equipment carries its own protection (the M07 medical control box, for example, carries a built-in fuse), but that protects that box's circuit; it does not replace protection on a direct-wired installation.

Fuse or circuit breaker?
Either can do the job if it is DC-rated for your voltage and sized by the same method; a breaker saves replacing fuses during fault-finding, a fuse is simpler and fails safe by opening permanently. What matters is the rating logic, not the device family. Do not fit an AC-only breaker in a DC circuit and assume it behaves the same.

Where exactly does the fuse go in the wiring?
In the positive feed, close to the power source — battery terminal or supply output — so the entire downstream run is protected. Our wiring guide shows where protection sits in the standard switch, wired-controller and remote layouts.

Two actuators, one supply: one fuse or two?
Protect the shared feed for the combined draw, and keep each actuator's branch consistent with its own full-load figure. If both actuators can run at once, "combined" means the sum from the table, at your voltage.

My supply is much bigger than the actuator needs. Does that change the fuse?
No. The fuse follows the actuator's draw and the wire's capacity, not the supply's maximum. An oversized supply makes correct fusing more important, not less: it can deliver far more fault current into a short than a small one can.

Circuit protection is unglamorous, and it is also the difference between a fault that costs you a fuse and a fault that costs you the wiring. Start from the full-load current in the table, place the fuse at the source, and treat every blown fuse as information. The full electrical specifications for each model are on its product page — and if your model's current is one we do not publish, ask us before you wire, not after the first fuse goes.