Will a Linear Actuator Hold Its Position With the Power Off? Self-Lock
It is the question behind a lot of returns and a lot of forum threads: the actuator lifts the load, the power goes off — a switch, a dead battery, a tripped breaker — and now what? Does the load stay where it is, or does it creep, sink, or slam back down? The answer lives in one specification that many buyers skip because it sounds like a footnote: the self-locking force. This guide explains what that number means, what it does not mean, and how the models in our range actually compare.
What self-locking force is — and is not
A typical electric linear actuator drives its rod through a worm gear and a screw. That gearing is very hard to drive backwards: push on the rod with the motor off, and the gear train resists instead of spinning the motor. The maximum static load the actuator can hold in position, unpowered, is its self-locking force.
Three distinctions matter:
- Self-locking force is not the push rating. Push is what the motor can move. Self-locking is what the gearing can hold while doing nothing. On most of our models the holding figure is higher than the push figure — sometimes much higher — because holding a load still is an easier job than moving it.
- Self-locking force is not a dynamic rating. It describes a stationary load at rest. A load that is bouncing, swinging, or being slammed by wind gusts is a different problem; our guide to static vs dynamic load covers that distinction in full.
- Self-locking is not a brake and not a safety device. It is a property of the gear geometry, not a rated protective function. Where a slipping load could hurt someone, holding force is one layer — never the only layer.
The numbers across our range
These are the self-locking figures we publish, next to the push and pull ratings so the relationship is visible. Where we do not publish a figure, the table says so — treat that as "ask us," not as "assume it holds."
| Model | Push | Pull | Self-locking (power off) |
|---|---|---|---|
| HH-LA-U1 | 900 N | 800 N | 1,500 N |
| HH-LA-U2 | 1,500 N | 1,100 N | 1,800 N |
| HH-LA-U3 | 6,000 N | 4,000 N | 8,000 N |
| HH-LA-U5 | 500 N | 400 N | 800 N |
| HH-LA-U6 | 7,000 N | 7,000 N | 9,000 N |
| HH-LA-U7 | 12,000 N | 12,000 N | 15,000 N |
| HH-LA-U8 | 4,000 N | 3,800 N | 4,000 N |
| HH-LA-U11 | 3,500 N | 3,500 N | 5,000 N |
| HH-LA-U4 | 6,000 N | 4,000 N | 6,000 N |
Read the pattern, because it teaches the selection rule. On the U3, a load the motor can just barely lift (6,000 N) sits well inside what the gearing can hold (8,000 N). On the U8, holding and pushing are the same figure, so a load at the very top of the push rating is also at the very top of the holding rating — no reserve. The check is never "is it self-locking?" (in this range, yes) but "how does my actual resting load compare with the self-locking figure?"
For the furniture line (HH-LA-U9, U10, U9-2), the track actuators (TP41, TP61, TP21) and the LC-01 lifting column, we do not publish a self-locking figure, and this article will not invent one. If power-off holding decides your furniture or rail mechanism, message us with the model and the load before ordering, and we will answer from the maker's data rather than from a guess.
The same trick, in rotary form
Self-locking is a worm-gear behaviour, which is why our worm gear motors show it too: the HH-370 and HH-31ZY hold their output shaft position with the power off, because the load cannot back-drive the worm. No holding-torque figure is published for them beyond their rated torque tables, so treat the property as "holds a stationary mechanism in place," and check any serious holding job against the rated torque on the product page.
When holding is not enough
Three situations where you should not rely on self-locking alone:
- Vibration and shock. A load that is shaken — on a vehicle, a trailer, a machine that vibrates — works against the gear train a little with every jolt. A mechanism that must hold for weeks in a vibrating environment deserves a mechanical latch, pin, or prop as well.
- Loads that can gain energy. A hatch the wind can catch, a lid that can be slammed, a panel someone can lean on: the force in the bad moment is not the resting weight you calculated. Our force calculation guide shows how to size for the worst position, not the average one.
- Anything carrying a person. On a bed or lift chair, the right answer to a power failure is a designed one: an emergency stop for the fault case, and on the HH-LA-U9-2 a hand-crank manual release that lets a caregiver lower the section by hand. Holding force keeps the bed still; it does not get anyone down.
The pre-order check
- Calculate the resting load honestly — the load the actuator carries when everything is stopped, in the worst geometry, not the lightest.
- Compare it with the self-locking figure, not the push figure. Your motor needs enough push to move the load; your gearing needs enough self-lock to hold it. Both checks have to pass.
- If the resting load is close to the self-locking figure, step up a model. The U3-to-U7 ladder exists precisely so that holding rarely has to run at its limit.
- If no figure is published for the model you want, ask. An unpublished number is not a zero and not an infinity — it is a question we can answer from the maker's specification before you order.
FAQ
Will the actuator hold at any point in the stroke, or only at the ends?
Anywhere. Self-locking is a property of the gear train, not of the end positions; the built-in limit switches stop travel at the ends, but the holding happens wherever the motor stops.
Can a strong enough load force the actuator backwards?
Yes — that is exactly what the self-locking figure quantifies. Below it, the gearing holds; above it, the load can back-drive the unit. This is why the comparison in the table matters more than the word "self-locking" itself.
Are all linear actuators self-locking?
No — it depends on the drive. Lead-screw and worm-gear drives, the designs used across our range, resist being driven backwards, which is what makes them self-locking. Ball-screw actuators are the exception: their efficiency runs both ways, so a load can drive them backwards with the power off, and they need a brake or continuous power to hold position. When comparing actuators, ask how a model holds its position, not only how hard it pushes.
Does self-locking work in both directions?
The figure is a holding capacity for a stationary load acting on the rod. In practice the check that matters is your resting load against the published figure for the model; where push and pull differ, size against the direction your load actually acts.
Does holding a load consume power or wear the actuator?
No power — that is the point of the feature — and no motor wear, because nothing is turning. The gearing simply resists.
What if the power fails with a person on a powered bed?
The section stays where it is; it does not drop. Getting the person down is a separate, designed path — on systems built around the HH-LA-U9-2, the hand-crank release described in our medical and nursing bed guide. Plan that path when you specify the bed, not during the outage.
Self-locking is the specification that decides what your mechanism does in the one moment you are not controlling it. Check the resting load against the holding figure before you order — and if the model you want does not publish one, ask us for it. Every actuator in this article carries a 12-month warranty, and the full specifications, including the figures quoted here, are on each product page.