Linear Actuator Duty Cycle, Explained: How Long Can You Actually Run I
Duty cycle is the spec most people skip when they buy a linear actuator — and the one that quietly decides how long the motor lives. This page explains what the percentage really means, how much rest your actuator needs between moves, and how to tell whether your application fits an intermittent-duty actuator at all.
What duty cycle actually means
Duty cycle is the share of time the motor is allowed to be powered within a repeating cycle:
Duty cycle = powered time ÷ total cycle time
A 10% duty cycle means that in any repeating window, the actuator should spend no more than 10% of the time running and the other 90% resting and cooling. It is not a limit on how far it can travel in one move — it is a heat budget.
The rest time follows directly from the run time:
Rest needed = run time × (100 − duty) ÷ duty
| One powered run | Rest at 10% duty | Rest at 20% duty |
|---|---|---|
| 30 seconds | 4.5 minutes | 2 minutes |
| 60 seconds | 9 minutes | 4 minutes |
| 90 seconds (a full 450 mm stroke at 5 mm/s) | 13.5 minutes | 6 minutes |
One of our heavy-duty models, the HH-LA-U8, is rated at a 10–20% duty cycle. Treat the rating as a range rather than a single number: the closer your load is to the actuator's maximum force, the harder the motor works and the more heat it makes — work to the 10% end. Running a light load, the 20% end is realistic.
For beds and recliners specifically, our furniture duty-cycle guide works the same idea out in minutes for that case.
Why heat is the limit
A compact DC actuator has no fan and no radiator. The brushed motor warms up every second it runs under load, and that heat has nowhere to go except into the housing and the room air while the actuator rests. Push past the duty rating repeatedly and the wear accelerates: brushes and windings age faster, gear grease thins, and the actuator starts to slow down and lose force long before it fails outright. Do not count on a protective cut-off to rescue an over-cycled actuator — the rating itself is the protection, and it only works if you design to it.
Applications that fit intermittent duty
Most real-world actuator jobs are naturally intermittent, which is why this class of actuator is so widely used:
- Solar trackers — a short move every few minutes, then a long rest
- Chicken coop doors and hatches — one or two moves a day
- Lift beds, recliners and TV lifts — brief adjustments, hours apart
- Dump trailers — a few lifts per load, with driving time as built-in rest
The pattern to avoid is continuous cycling: an actuator that must extend and retract every few seconds, all day — indexing, sorting, or pumping-style reciprocation — will live outside its heat budget no matter how strong it is. That work belongs to a drive designed for continuous duty, and no honest seller should tell you otherwise.
Three ways to stay inside the rating
- Oversize the actuator. Pick a model whose maximum force is comfortably above your actual load — a mid-range job that a smaller unit could just barely move will run cooler on a heavier model like the HH-LA-U11. An actuator working at half its rating draws less current, makes less heat, and tolerates a busier cycle pattern than one straining at its limit.
- Batch the moves. If your mechanism needs several short moves, check whether the job can be done in fewer, planned moves with a proper rest after, instead of constant small adjustments.
- Shorten the powered time per move. A faster actuator finishes the same stroke in less time, so each move spends less of the heat budget. Stroke length matters the same way — do not buy more travel than your mechanism uses.
Questions we hear
What happens if I exceed the duty cycle once?
A single overrun is unlikely to kill an actuator; the damage from over-cycling is cumulative. If the housing feels hot, stop and let it cool completely before the next move — and treat it as a sign the cycle pattern needs rethinking.
Does duty cycle change between 12V and 24V?
The idea is the same at both voltages: it is a heat limit, expressed as a percentage. What changes with voltage is the current drawn for the same load, not the need for rest.
How do I check my application before ordering?
Count it: how many moves per hour, how many seconds per move, and how heavy the load is relative to the actuator's rating. If the math puts you past 20% powered time, or you are not sure, tell us the pattern before you order and we will tell you honestly whether an intermittent-duty actuator fits — or whether you should be looking at something else.