Can You Control the Speed of a Linear Actuator?

Short answer: no — not after you buy it. The speed of an electric linear actuator is set by its gear ratio, which is fixed when the model is built. Our standard controllers switch the actuator on and off and reverse its direction; they do not have a speed dial. If the speed matters for your project, it is a purchase decision, not an adjustment. This guide explains why, shows the speeds our models actually run at, and covers the honest options — including the one question buyers ask most, whether a PWM speed controller will work.

Why the speed is fixed

Inside the actuator, a small DC motor turns a gearbox, and the gearbox turns a screw. The gear ratio decides how fast the rod moves and how much force it delivers: a high reduction gives more force and less speed; a low reduction gives more speed and less force. That ratio is machined into the gearbox. Nothing on the outside — not the switch, not the remote, not the power supply — changes it.

Our controllers reflect that. The wired control kit and the wireless remote kit do three things: extend, retract, and stop. There is no speed setting, because there is nothing in the actuator for a speed setting to adjust. See our wiring guide and controller compatibility guide for what our controllers do and do not do.

So if you need a bed to rise in 20 seconds rather than 40, or a vent to open slowly rather than quickly, the time to decide is before you order — pick the model whose published speed gives you the travel time you want.

The speeds, verified

Two speeds are published for each model: no-load speed (the rod moving freely) and full-load speed (the rod moving its rated force). The full-load number is the one that matters, because that is the speed your mechanism will actually see.

Model Speed, no-load / full-load Force
HH-LA-U1 10 / 7 mm/s 900 N (pull 800 N)
HH-LA-U2 6 / 4.5 mm/s 1500 N (pull 1100 N)
HH-LA-U8 5 / 3.5 mm/s 4000 N (5 mm/s grade)
HH-LA-U11 3.5 / 2.2 mm/s 3500 N
HH-LA-U3 5 / 3.5 mm/s 6000 N (pull 4000 N)
HH-LA-U6 9 / 7 mm/s 7000 N
HH-LA-U7 6.5 / 4.5 mm/s 12000 N

To work out a travel time, divide the stroke by the full-load speed. A U3 at 3.5 mm/s takes about 43 seconds to travel a 150 mm stroke under load (150 ÷ 3.5 ≈ 43). A U1 at 7 mm/s covers the same stroke in about 21 seconds. If 43 seconds feels slow for a cabinet door and 21 seconds feels right, that is a model choice — the U1 and the U3 are different tools, and the speed table is how you tell them apart. Our speed guide covers the selection in full.

One thing to notice: the heavy models are slow, and on most mechanisms that is a safety feature, not a flaw. A 12000 N actuator moving a heavy lid at 4.5 mm/s gives everyone time to get clear; the same lid at 20 mm/s would be a hazard. Speed and force trade against each other, and the trade is visible in the table.

The force-speed trade-off, in one model

The U8 shows the trade-off most clearly, because it is sold in four speed grades from the same manufacturer. Only the 5 mm/s grade is sold in our store; the other three are custom order — ask us first.

U8 speed grade Speed, no-load / full-load Force (push / pull / self-locking)
5 mm/s grade (in store) 5 / 3.5 mm/s 4000 / 3800 / 4000 N
10 mm/s grade (custom order) 10 / 7 mm/s 2000 / 1800 / 2000 N
15 mm/s grade (custom order) 15 / 10 mm/s 1500 / 1200 / 1500 N
26 mm/s grade (custom order) 26 / 20 mm/s 800 / 600 / 800 N

Double the speed, halve the force — roughly. That is the whole story of actuator speed: you are always buying a point on a curve, and moving along the curve costs force. A buyer who wants the 26 mm/s grade and the 4000 N force is asking for a point that does not exist on this curve, in this model or any other. If your mechanism needs both speed and force, the answer is a bigger model or a different mechanism, not a faster version of the same one.

Does 12V or 24V change the speed?

No, not in the way buyers usually hope. We publish one speed per model, not one speed per voltage — the U1 runs 10 / 7 mm/s whether you buy the 12V or the 24V configuration. What changes with voltage is the current: the 24V versions draw roughly half the current of the 12V versions at the same force, which is why 24V is easier to wire over long runs. Voltage is a wiring decision, not a speed decision. Our 12V vs 24V guide and power supply guide cover the trade-offs.

Do not try to speed an actuator up by feeding it a higher voltage than it is rated for. A 12V actuator on a 24V supply will run faster for a short while and then fail — the motor overheats, the duty cycle rating no longer means anything, and the damage is not a warranty matter. Match the actuator voltage to the supply. Always.

What about PWM speed control?

PWM (pulse-width modulation) speed controllers exist in the market: they switch the power on and off thousands of times a second, and the motor runs slower on average. Some buyers ask whether they can fit one to our actuators. Here is the honest answer: we do not sell a PWM speed controller, and we have not tested third-party PWM controllers with our actuators or our control kits. So we cannot promise that a given PWM controller will work well with a given model, hold speed steadily under load, or behave sensibly with our built-in limit switches.

That is not a no — it is a "we have not verified it, so ask us first." If your project genuinely needs variable speed, tell us the speeds you need before you order. The usual answer is a different speed grade (the U8 table above is the clearest example), a different model, or a mechanism that does not need the speed changed at all — a slower model with the right stroke often does the job better than a fast model throttled down.

Two related facts, so the picture is complete. First, slowing an actuator down does not change its duty cycle rating: the U7 is rated 25%, the U2, U3, U8, and U11 at 10–20%, and the rating still applies however the speed is achieved. Our duty cycle guide explains the rating. Second, slowing an actuator down does not raise its holding force. The grades sold in our store hold: the U1 1500 N, the U2 1800 N, the U3 8000 N, the U6 9000 N, the U7 15000 N, the U8 4000 N (5 mm/s grade), and the U11 5000 N — and for the U8, the holding force follows the speed grade, as the table above shows. See our self-locking guide for what holding force means.

If you need a specific speed

Work backwards from the mechanism. Decide the travel time you want, divide the stroke by that time to get the full-load speed you need, then find the model whose published full-load speed matches — with the force to spare, because speed without enough force is a stalled actuator. If no model in the store matches, ask us: the U8's other speed grades are a custom order, and other models may have grades we can source. The question costs nothing before the order; after the order, the speed is fixed.

FAQ

Can I slow down my actuator with the remote or the control box?
No. Our wired and wireless controllers extend, retract, and stop. They have no speed setting, because the speed is fixed by the gearbox inside the actuator.

Can I use a third-party PWM speed controller?
We do not sell one, and we have not tested third-party PWM controllers with our actuators. Ask us before you try — tell us the model and the speeds you need, and we will tell you whether a different speed grade or model is the better answer.

Will 24V make my actuator faster than 12V?
No. We publish one speed per model for both voltages. The 24V versions draw roughly half the current, which makes wiring easier — that is the difference voltage makes.

Can I run a 12V actuator on 24V to make it faster?
No. It will run faster briefly and then fail from overheating. Match the actuator voltage to the supply, always.

How do I work out the travel time?
Divide the stroke by the full-load speed. A 150 mm stroke on a U3 at 3.5 mm/s takes about 43 seconds under load; on a U1 at 7 mm/s, about 21 seconds. Use the full-load speed, not the no-load speed — the no-load number is the rod moving freely, which is not your mechanism.

Does a slower speed mean I can run it longer?
No. The duty cycle rating — 25% for the U7, 10–20% for the U2, U3, U8, and U11 — still applies. Running slower does not buy more running time.

What if I need a speed no model in the store offers?
Ask us before ordering. The U8's other speed grades are available by custom order, and we can check other models' grades. The question is free; the wrong model is not.

Actuators in this guide carry a 12-month warranty; check the product page for the current terms. Our U-series actuators are covered by a UDEM certificate of conformity (valid to 2028-04-23) for the JS-TGZ-U1–U12 range — see our CE guide for what the certificate covers. Brackets fit the U1/U2 (angled bracket) and U3 (U-bracket) only, are ordered with the actuator, and are not sold separately. For volume, distributor, or OEM orders, see our Bulk & OEM/ODM page.

For the rest of the project, start with our how to choose an electric linear actuator, our selection guide, and our full model comparison. Related reading: our speed guide, force selection guide, 12V vs 24V guide, controller compatibility guide, duty cycle guide, and shock loads guide cover the neighbouring decisions.

Back to Home