HH-LA-U6 Up Close: 7,000 N Both Ways, with a Clutch That Forgives Jams
Most actuators in our range are honest about being one-directional specialists: the push rating is the headline and the pull rating is something smaller. The HH-LA-U6 is the exception. It pushes 7,000 N and pulls the same 7,000 N, it carries a clutch that slips before a jam can break something, and it reports its end positions back to your control system. It is the model we point to when the mechanism is heavy, works outdoors, and cannot be watched. This article goes through its published numbers: what each one means, where the U6 earns its price, and where a smaller model is the smarter buy.
The numbers, straight from the datasheet
- Maximum push force: 7,000 N (1,574 lbs)
- Maximum pull force: 7,000 N — the same as push
- Maximum self-locking load: 9,000 N — it holds position with the power off
- Voltage: 12V or 24V DC
- Motor: 100W brushed DC
- Stroke options: 200–600 mm (8″–24″); OEM custom strokes from 15–1,000 mm on request
- Speed: 9 mm/s with no load, 7 mm/s under load
- Current draw: 12V — 3.6A no load / 16A under load; 24V — 1.8A no load / 9A under load
- Duty cycle: 10–20%
- Operating temperature: −40°C to 65°C
- Noise: under 65 dB
- Protection rating: IP65
- Drive: trapezoidal screw, with built-in clutch overload protection
- End control: built-in limit switch with signal output
- Service life: 20,000–30,000 cycles
- Installation length: stroke + 250 mm, retracted
The full datasheet, dimension drawing, and installation reference are on the HH-LA-U6 product page, and our model comparison table puts these figures next to every other actuator in the range.
Equal push and pull — and a clutch for the day something jams
Equal ratings in both directions change how you can design. A mechanism that lifts a platform and then pulls it back down against resistance — a loaded scissor stage, a heavy hatch working against seals and gravity — can be sized once, honestly, instead of derating the return stroke. The self-locking figure completes the picture: 9,000 N held with the power off, no brake and no standby draw. What self-locking does and does not promise is set out in our self-locking guide.
The clutch is the feature buyers only appreciate after the first jam. If the load seizes mid-travel — a guide rail binds, debris lands in the mechanism, an operator drives the platform into an obstruction — the built-in clutch slips instead of transmitting the motor's full torque into the screw and gearbox until something strips. It is overload protection, not a licence to run into things: treat a slipping clutch as a fault to investigate, not a limit switch. But as a last line of defence on equipment that works unattended, it is the difference between a stopped machine and a broken one.
Current is the number your wiring has to respect
Sixteen amps at 12V under load is real current. It decides your power supply, your cable gauge, and your fuse before it decides anything else, and it is the strongest argument for the 24V version in a fixed installation: the same work at 9A, with half the voltage drop over a long cable run. Our 12V vs 24V guide, the power supply guide, and the fuse sizing guide all work from these published figures. At 7 mm/s under load, a 400 mm stroke takes about 57 seconds end to end — the deliberate pace of a unit geared for force, and the duty cycle of 10–20% still applies: this is a machine for deliberate movements with real pauses, not continuous cycling.
The signal output deserves a mention because it is easy to miss in the spec table: the built-in limit switch reports the end positions, so a control system can confirm the actuator actually arrived, not merely that it was told to move. On an unattended platform or a farm installation checked once a day, that confirmation is worth more than another 500 N.
Built for the places actuators usually die
IP65 sealing and a −40°C to 65°C operating range put the U6 where lighter units do not belong: farm equipment, off-highway machinery, and outdoor mechanisms that work through winter. Our articles on actuators in cold weather and on off-highway and construction machinery cover the application thinking; the U6 is usually the model those articles end up pointing at. One honest counterweight: at under 65 dB it is not a quiet actuator. Heavy gearing makes noise, and in a living space you will hear it — the furniture-duty models exist precisely because this trade-off runs the other way there.
Where the U6 fits
- Heavy platforms and lifts — loads that must be pulled down as firmly as they are pushed up, held at 9,000 N with the power off.
- Farm and off-highway equipment — cold starts, dust, wash-down weather, and long cable runs on 24V.
- Unattended mechanisms — clutch protection against jams, and signal output so the control system knows the travel completed.
- Industrial access and hatch work — heavy panels where the return stroke works against seals and gravity, not just the panel's weight.
Where it does not
- Short strokes. Standard strokes start at 200 mm, and the installed length is the stroke plus 250 mm — a 200 mm unit already measures 450 mm retracted. Compact mechanisms belong to the smaller models; check the space with our retracted-length guide before assuming.
- Quiet indoor furniture. Under 65 dB is honest industrial noise. A recliner or a bed mechanism wants a furniture-duty unit.
- Loads beyond 7,000 N. The answer is the 12,000 N HH-LA-U7, not a U6 run at its limit and hoped over.
- Continuous cycling. A 10–20% duty cycle is a real limit, clutch or no clutch.
Controls and mounting — what is not in the box
The U6 is the actuator alone. Controllers are sold separately: pair it with a wired or wireless control kit, or a control box from our controller range, and check the pairing against our controller compatibility guide before ordering. Mounting brackets are likewise not included with any actuator, and the bracket add-on packs we sell fit the U1/U2 (angled) and U3 (U-shaped) only — for the U6, plan your mounting from the dimension drawing on the product page, and talk to us if the interface is non-standard.
Certification
The HH-LA-U6 is covered by our CE certificate UDEM M.2023.206.C84513, valid to 23 April 2028. If your project needs a different model and CE documentation matters to it, name the model when you enquire — for models outside the certified list we will source and confirm the documentation before you order, rather than ask you to take a logo on faith. Our guide to telling a real certificate from a printed logo explains what to check, on ours or anyone's.
Questions we hear
Can it really pull the same load it pushes? Yes — 7,000 N is the rating in both directions, which is unusual enough that the product page states both figures separately. Size your mechanism against 7,000 N either way, and against the 9,000 N self-locking figure when it is holding still.
How long is it, retracted, with a 400 mm stroke? 400 + 250 = 650 mm between mounting points. That is the U6's real space claim, and it is why compact installations rule it out before force ever comes up.
What happens if the platform jams halfway? The clutch slips to protect the screw and gearbox, and the correct response is to find the obstruction — the clutch buys you a stopped machine instead of a stripped one, not permission to keep driving.
Is the price on the product page the whole story? The product page carries the current price and the full document set. Budget separately for a controller — it is not bundled into the actuator price, and we would rather say that plainly here than surprise you at checkout.
If your numbers land anywhere near the U6's limits — force in either direction, a long stroke, a tight retracted space, a cold site — send them to support@hyhavenllc.com or through the product page and we will confirm the sizing with you. Two minutes of checking is the cheapest insurance in any linear motion project.