Thread Tolerance Explained: What 6g and 6H Actually Decide on a Bolt
Ask for "an M10 bolt" and you have specified a diameter and, by convention, a pitch. You have not specified how the thread is allowed to vary — and thread tolerance is where bolts that are all nominally M10 differ in the hand: one spins on freely, one needs a wrench from the first turn, and one assembles fine until the plating goes on, after which it does not assemble at all. The tolerance class — 6g, 6H, and their relatives — is the short code that decides this, and it belongs on any custom bolt drawing that cares about fit. This article explains what the code means, why 6g/6H became the world's default pairing, and the plating interaction that makes the class worth specifying rather than assuming.
Reading the code: a letter and a number
A metric thread tolerance class has two parts. The number is the tolerance grade — how wide the allowed variation is; smaller is tighter and more expensive to hold. The letter is the position of that tolerance zone relative to the nominal size — the fundamental deviation. By convention, external threads (bolts) take lowercase letters and internal threads (nuts, tapped holes) take uppercase. So 6g is a bolt thread: grade 6, position g. 6H is a nut thread: grade 6, position H. The pairing 6g/6H is the standard medium fit for commercial fasteners — the combination the overwhelming majority of the world's metric bolts and nuts are made to, and the one to assume is meant when a drawing says nothing more. Our metric thread guide covers the size and pitch side of the designation that the class completes.
Why position g exists: the plating allowance
The letter is where the practical story lives. Position H on an internal thread puts the tolerance zone starting exactly at nominal — no built-in clearance. Position g on an external thread shifts the zone slightly below nominal: the bolt thread is made a touch under size on purpose. That small, deliberate clearance does two jobs. It guarantees the standard pairing assembles freely by hand across the whole tolerance range, and it leaves room for a coating. Electroplated zinc adds real thickness to a thread's flanks, and a thread made dead-on nominal before plating can come back over size after it. The g allowance is sized to absorb a normal commercial plating thickness — which is why the standard class and standard zinc plating coexist without drama, and why the drama starts exactly where the allowance runs out: heavy coatings. Hot-dip galvanizing is far thicker than the g allowance, which is why galvanized bolting uses its own arrangements — oversize-tapped nuts and matched assemblies — rather than ordinary 6g/6H parts mixed at random. Our surface treatments guide covers the coating thicknesses behind this.
When to specify something other than the default
- Thick or special coatings: if the finish is more than a standard commercial plate, the tolerance class and the coating must be specified together, so the thread is made with the coating in mind rather than rescued after it.
- Stainless assemblies: fit still matters — a tight, dry stainless pairing is where galling starts, as our stainless versus carbon steel guide explains; the standard class plus correct assembly practice is the usual answer, not a looser thread.
- Precision mechanisms: where thread play itself is a functional problem, tighter grades exist — at tighter-grade prices, in machining time and in gauging. Specify them for a reason, not as a reflex.
- Rolled versus cut threads: either process can hold the standard classes; the choice between them is about strength and volume, covered in our thread rolling guide — but the class must be achievable after any finishing, which is the drawing's job to state.
Checking: what gauging proves
Tolerance classes are verified with go/no-go thread gauges: the go gauge must pass, the no-go must not, and together they prove the thread sits inside its zone — the practical meaning of "6g" on an inspection bench. Our inspection guide sets out where thread gauging sits among the other checks a finished fastener gets. A class on the drawing without gauging behind it is a wish; gauging without a class on the drawing has nothing to check against. The pair is the specification.
Our practical advice is the same as for material and coating: if fit matters to your assembly — and after plating, it does — write the class on the drawing ("M10 × 1.5 – 6g" is the whole sentence), and we will confirm it, with the coating, at quotation. If the drawing is silent we produce to the standard commercial classes, as the world's default expects. Drawings and questions to support@hyhavenllc.com — thread fit is a cheap thing to settle on paper and an expensive one to settle on an assembly line.