How to Automate a Swing Gate with a Linear Actuator
A swing gate opener is, mechanically, a linear actuator with brackets. One end mounts to the gate post, the other to the gate leaf, and the actuator extends and retracts to swing the gate on its hinges. Purpose-built gate operators work exactly this way — a telescopic actuator arm between post and leaf — which is why a standard electric linear actuator, sized honestly, is a legitimate DIY route to an automatic gate. The sizing is the whole job: get the leverage, the stroke, and the speed right, and the rest is wiring and weatherproofing.
This guide covers swing gates only. A sliding gate — one that rolls sideways along a track — is driven by a motor and a toothed gear rack, not by a linear actuator, and this guide will not pretend otherwise.
Step 1: work out the force — it is leverage, not weight
A gate's weight is not the force the actuator sees. What the actuator feels is the gate's weight multiplied by the leverage of the mounting geometry: the distance from the hinge to the gate's center of gravity, divided by the actuator's effective arm at the hinge. The worst moment is at the start, with the gate closed and the actuator at its poorest angle — the same lesson as our dump trailer guide.
Two worked examples, with the assumptions stated so you can see the method rather than copy the answer:
Example A — light wooden gate. Gate 40 kg (about 392 N), hinge-to-center-of-gravity distance three times the actuator's effective arm. Required force ≈ 392 × 3 ≈ 1,180 N. A HH-LA-U2 at 1,500 N covers it with margin.
Example B — heavy steel gate. Gate 80 kg (about 784 N), same 3:1 leverage. Required force ≈ 784 × 3 ≈ 2,350 N. A HH-LA-U11 at 3,500 N covers it.
Example C — large farm gate. Gate 120 kg (about 1,176 N), 3:1 leverage. Required force ≈ 3,530 N. That is past the U11 — step up to the HH-LA-U3 at 6,000 N, or the HH-LA-U6 at 7,000 N.
Do not order from these examples. Measure your own gate: weigh it (or estimate from material and size), measure hinge to center of gravity, measure where you can mount the actuator, and work out your own ratio. Our force guide walks through the same calculation in general terms. When the number lands close to a model's rating, go one size up — a gate that binds in winter or drags on a sagging hinge will ask for more force than the clean calculation says, and an actuator working well under its rating lasts longer than one at its limit.
| Model | Push force | Fits |
|---|---|---|
| HH-LA-U1 | 900 N | Very light garden gates only |
| HH-LA-U2 | 1,500 N | Light wooden gates |
| HH-LA-U11 | 3,500 N | Medium steel gates |
| HH-LA-U3 | 6,000 N | Heavy gates, large farm gates |
| HH-LA-U6 | 7,000 N | Heavy gates with poor leverage |
| HH-LA-U7 | 12,000 N | The heaviest gates — with the speed cost below |
Wind matters too: a solid-panel gate catches wind like a sail, and a gust adds a dynamic load on top of the static calculation. If your gate is solid and exposed, size up and read static vs dynamic load before you order. An open-bar gate is kinder to the actuator than a solid one.
Step 2: stroke and geometry — measure the two points
The stroke you need is not the gate's width. It is the change in distance between the two mounting points — post bracket and gate bracket — as the gate swings from closed to open. Mount the brackets, measure that distance closed, measure it open, and the difference is the stroke. Buy the stroke that covers the difference with a little spare travel; do not buy far more than you need, because a longer stroke means a longer retracted actuator that has to fit between the post and the gate when closed.
Retracted length is stroke plus the model's installation length: stroke + 120 mm on the U11, stroke + 110 mm (or + 120 mm for strokes of 300 mm and above) on the U8, and stroke + 175 mm pin-to-pin on the U3. Check that retracted length against the space you actually have before ordering — our stroke measurement guide and the retracted-length space check show how. Retail strokes run to 450 mm; beyond that is a custom conversation, not a shopping-cart option.
Mounting hardware is part of the purchase decision, not an afterthought: our actuators ship without brackets, and the brackets we sell fit the U1, U2, and U3 only. For the U6, U7, and U11, plan your own post and gate brackets — solid steel, through-bolted, with pivot pins that let the actuator swing freely as the geometry changes. An actuator forced to bend sideways will wear out fast; our mounting guide covers the pivot principle.
Step 3: speed — a gate is not fast, and you should know that before ordering
Heavy actuators are slow. At full load, a 200 mm stroke takes about 29 seconds on the U1 (7 mm/s), about 44 seconds on the U7 (4.5 mm/s), about 57 seconds on the U8 (3.5 mm/s, sold grade), and about 91 seconds on the U11 (2.2 mm/s). A longer stroke scales in proportion. That is the honest number: your gate will take the better part of a minute to open. For a driveway gate, that is usually fine — you press the remote as you turn in. If you need a ten-second gate, a linear actuator is the wrong drive, and no honest seller should tell you otherwise. Our speed guide covers the force-speed trade-off in general.
Step 4: power and control
A gate post rarely has mains power next to it, so most DIY gate setups run from a 12V battery, often kept charged by a small solar panel. Match the actuator voltage to your battery: 12V or 24V, both available across the range. What changes is the current — the same job at 24V draws roughly half the current it draws at 12V. Our 12V vs 24V guide covers the trade-offs, and our battery power guide covers vehicle-battery and off-grid setups.
Size the fuse from the full-load current, not from a guess:
| Model | Full-load current, 12V | Full-load current, 24V |
|---|---|---|
| U1 | 3.0 A | 1.8 A |
| U2 | 3.8 A | 2.0 A |
| U3 | 8.5 A | 3.8 A |
| U6 | 16.0 A | 9.0 A |
| U7 | 20 A | 10.5 A |
| U8 | 7 A | 4 A |
| U11 | 6.0 A | 3.0 A |
Our fuse and circuit protection guide sizes protection from this same table. If the battery sits far from the gate, read the long-wire voltage drop guide before running cable.
Control is the easy part: a rocker switch reverses the actuator directly, and our wireless and wired remote kits add operation from the car or the house. Controllers are sold separately — actuators ship without one. See the wiring guide and the controller compatibility guide. Gate use is naturally intermittent — a few cycles a day — which suits these actuators: the only duty-cycle ratings we publish are the U8 and U11 at 10–20%, and a gate lives comfortably inside that pattern.
Step 5: weather
A gate actuator lives outside, permanently. Pick by the IP rating: the HH-LA-U7 at IP66 is dust-tight and protected against powerful water jets — the right pick for a fully exposed post. The HH-LA-U11 at IP65 is dust-tight and protected against water jets — fine for rain and rinsing, but do not submerge it. Our IP ratings guide explains what each digit promises. For cold climates, the U7 is rated −26 to +60°C; our cold weather guide explains what that rating does and does not promise. We do not publish IP ratings for the U3 or U6, so if your gate post is fully exposed to driving rain, pick from the models whose ratings we state here.
Safety — read this before you build
A powered gate can injure a person, a child, or a pet caught in it, and a gate that closes on a car is an expensive mistake. Three things are not optional:
- Entrapment protection is a separate function. Purpose-built gate operators include obstacle detection and auto-reverse. Our switch and remote kits do not provide those functions — they drive the actuator forward and back on command, nothing more. If your gate needs entrapment protection (and any gate people walk through does), you must add proper safety devices — photoelectric sensors, safety edges, or a controller with those inputs — and verify they work before the gate enters service.
- Check your local code. In the United States, gate operators fall under the UL 325 safety standard; other countries have their own rules. Do not assume a DIY build is exempt.
- Keep pedestrians separate. Automatic gates are designed for vehicle traffic. Pedestrians should use a separate pedestrian gate, and children should not play on or around a powered gate.
A gate that holds its position when the power fails is part of the same safety picture: our actuators hold unpowered by self-locking gearing — U7 15,000 N, U6 9,000 N, U3 8,000 N, U11 5,000 N. The full rule, including where self-locking is not enough, is to compare your resting load with the holding figure. Holding force is a property of the gearing, not a brake and not a safety device.
Questions we hear
Can one actuator open a double gate?
No — one actuator drives one leaf. A double gate needs two actuators, one per leaf, and they will not stay synchronized on a plain switch: each leaf needs its own control, or a controller designed for the pair. Our dual-actuator synchronization guide explains what actually works and what does not.
Will the gate stay shut in a storm with the power off?
If the wind load on the closed gate is below the model's published self-locking force, yes. Size for the gust case, not the calm case — and remember that a solid-panel gate in a storm is a dynamic load, not a static one.
What if the actuator stops mid-travel?
Work through the troubleshooting checklist — power, fuse, wiring, and limit switches, in that order. All of our actuators have built-in limit switches that stop travel at the ends of the stroke; if the gate stops short, the usual cause is a power or wiring problem, not the actuator. Our limit switch guide explains how the built-in switches work.
How long will it last outdoors?
That depends on the environment and the mounting more than on any single number. Keep the pivots free, keep the rod clean, check the mounts seasonally, and follow the maintenance guide. Actuators carry a 12-month warranty.
The actuators in this guide
- HH-LA-U2 1,500 N — light wooden gates
- HH-LA-U11 3,500 N, IP65 — medium steel gates
- HH-LA-U3 6,000 N — heavy gates, large farm gates
- HH-LA-U6 7,000 N — heavy gates with poor leverage
- HH-LA-U7 12,000 N, IP66 — the heaviest gates
- HH-LA-U1 900 N — very light garden gates